Division 01

HVAC engineered for climate, load and lifetime cost.

From central plant to the last diffuser, QAAC selects, installs, tests and balances air conditioning and ventilation systems that hold their performance long after handover.

Our approach

Selection is an engineering decision, not a catalogue pick.

Saudi ambient conditions punish under-engineered systems. We start from measured loads, occupancy patterns and part-load hours, then select equipment that stays efficient at the conditions the building actually sees.

Installation is carried out by our own supervised teams, and every system leaves us tested, balanced and documented — with the client's facilities team trained on it.

Products

Equipment we supply and install.

Sourced from established manufacturers, engineered into a system that works as a whole.

Water-Cooled & Air-Cooled Chillers

Water-Cooled & Air-Cooled Chillers

Central cooling plant from 50 to 1,500 TR, selected against real building load profiles and part-load efficiency targets.

  • Screw & centrifugal
  • Low-noise packages
  • BMS-ready controls
Air Handling Units

Air Handling Units

Double-skin modular AHUs with filtration, heat recovery and EC plug fans for offices, hospitals and clean environments.

  • Hygienic options
  • Heat recovery wheels
  • EC plug fans
Fan Coil Units

Fan Coil Units

Concealed and cassette terminal units for zone-level comfort, with quiet operation and accessible maintenance.

  • Ducted & cassette
  • 2 and 4 pipe
  • Low sound power
VRF / VRV Systems

VRF / VRV Systems

Variable refrigerant systems for buildings that need zoned control, simultaneous heating and cooling, and phased fit-out.

  • Heat recovery
  • Long pipe runs
  • Central controllers
Ductwork & Insulation

Ductwork & Insulation

Fabricated, installed and leak-tested ductwork with thermal and acoustic insulation to specification.

  • GI & pre-insulated
  • DW/144 leak testing
  • Acoustic lining
Ventilation & Smoke Control

Ventilation & Smoke Control

Car park, kitchen and industrial extract, plus stair pressurisation and smoke management systems.

  • Jet fan systems
  • Kitchen extract
  • Pressurisation

Services

What comes with the equipment.

Load calculation & selection

Heat load modelling, plant sizing and equipment schedules.

Installation

Directly supervised mechanical installation and pipework.

Testing & balancing

Air and water balancing with recorded commissioning data.

Maintenance

Planned preventive maintenance and performance monitoring.